Xi'an Taijin Industrial Electrochemical Technology Co., LTD.
|
Price: | 50.0 USD |
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Shaanxi, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
TAIJIN Titanium Anode for Sodium Hypochlorite Generator
By electrolyzing sea water or salt water, sodium chloride in sea water or salt water is oxidized into hypochlorous acid sodium, and it can generate the hypochlorous acid by hydrolysis, then hypochlorous acid decomposes further to form new ecological oxygen, new ecological oxygen has strong oxidizing, they can make protein and other cells of bacteria and virus degeneration, thus kill pathogenic microbes, and effectively prevent microbial contamination.
Application
Power plant cooling water antifouling, large vessel ballast water treatment, small hypochlorous acid sodium generator, life sewage treatment etc.
² Specification and performance
All the products are customized as client's request.
Specification | Unit | Parameter |
Ruthnium | G/m2 | ≥6.0 |
Chlorine evolution potential | (Vs.SCE)/V | ≤1.13 |
Polarizability | /m V | ≤40 |
Accelerated life | h | ≥120 |
Homogeneity | % | ≤15 |
Working life | Y | ≥5 |
a) Temperature:0~40℃
b) Concentration of electrolyte:30~50g/L
² Substrate:
Titanium ASTMB265 Grade 1
Chemical Composition | N | C | H | O | Fe | Ti | other |
Maximum Content | 0.03% | 0.08% | 0.015% | 0.18% | 0.20% | 99% | 0.4% |
² Coating: Ruthenium base mixed coating, customized by client's request.
² Current Efficiency Test:
Test Conditions | Results |
3.5% NaCl solution, current:1500A/m2, temperature:15±1℃ | >85% |
² Accelerated Life test:
Test Conditions | Results |
1mol/l H2SO4, current:20000A/m2, temperature:40±1℃ | >85% |